Hantek HBT3561A Battery Tester (max 110v)
Buy it now
$1,662.00 excl. GST
$1,911.30 incl. GST
Shipped Nationwide
In Stock with Supplier est. 10 days lead time
When will I receive it?
10 days sent via NZ Post (estimated lead time - requires sea freight)
Contact Us for a firmer ETA.
Description
The HBT3561A is a high-resolution battery internal resistance tester for measuring battery resistance and voltage. It uses an AC four-terminal method for accurate measurements and supports fast testing with built-in comparison and data handling functions.
Features
- 6 1/2-bit high-resolution battery internal resistance measurement
- AC four-terminal measurement method reduces the effect of test lead impedance
- 0.1 μΩ resistance resolution and 10 μV voltage resolution
- Independent resistance and voltage comparator functions
- Short-circuit zero adjustment helps remove instrument and environment offset errors
- Fast, medium and slow sampling rates, with high-speed measurement down to approximately 40 ms
- Measurement results can be saved to a USB drive for later analysis
- Supports USB screenshots and firmware upgrades via USB drive
- Statistical functions include average, maximum, minimum and standard deviation
- Standard interfaces include RS232/485, LAN, EXT I/O, USB Host, USB Device and analogue output
High precision and wide range
6 1/2, the voltage measurement range reaches 2000V, the resistance measurement range is 0 ~ 3.6kΩ, which has a high-precision and rapid measurement characteristics of the battery internal resistance testing instrument. Field meets your needs.
Comparator function
Resistance and voltage are independent, and the function of displaying and output the measurement results will help you better understand the working status of your circuit or equipment.
Save/Load Function
The startup settings can be saved to the internal or U disk. There is no need to perform tedious application settings every time you use. Press the corresponding power-on settings button to easily load the previously saved application settings.
Three-speed sampling rate
The sampling rate can be changed in three stages (Fast/Horotelic/Slow), and the appropriate sampling rate can be selected according to different testing needs. The fastest high-speed measurement can be about 40 ms. The lower the sampling rate, the higher the testing accuracy.
Correction function
The calibration is divided into voltage calibration and resistance calibration, which is used to compensate the bias voltage or gain drift of the internal circuit of the instrument to improve the test accuracy.
Statistical function
Calculating a variety of statistical indicators, including but not limited to Average, Max, Min, Parent Standard Deviation, etc., makes it easy to plot the normal distribution and helps you visualize the normal distribution of your measurements.
Rich configuration interfaces
Standard configuration includes RS232/485, LAN, EXT I/O, USB Host, USB Device, and ANALOGOUTPUT interfaces. With rich interfaces, it is a measuring instrument suitable for building battery production inspection circuits.
| Model | HBT3561A (this model) | HBT3562A | HBT3563A | HBT5563A | HBT3564A | HBT3565A | HBT5566A | HBT3566A | |
|---|---|---|---|---|---|---|---|---|---|
| Voltage Measurement | Range | 110V | 210V | 360V | 360V | 1100V | 1600V | 2000V | 2000V |
| Max. Display | 121V | 231V | 396V | 396V | 1210V | 1760V | 2200V | 2200V | |
| Resolution | 1 μV | 10 μV | |||||||
| Accuracy | ±0.01% rdg ±3 dgt | ||||||||
| Resistance Measurement | Range | Max. Display | Resolution | Measurement Current | Accuracy | ||||
| 3 mΩ | 30 mΩ or more | ||||||||
| 3 mΩ | 3.6 mΩ | 0.1 μΩ | 100 mA | ±0.5% rdg ±10 dgt | ±0.5% rdg ±5 dgt | ||||
| 30 mΩ | 36 mΩ | 1 μΩ | 100 mA | ||||||
| 300 mΩ | 360 mΩ | 10 μΩ | 10 mA | ||||||
| 3 Ω | 3.6 Ω | 100 μΩ | 1 mA | ||||||
| 30 Ω | 36 Ω | 1 mΩ | 100 μA | ||||||
| 300 Ω | 360 Ω | 10 mΩ | 10 μA | ||||||
| 3600 Ω | 3610 Ω | 100 mΩ | 10 μA | ||||||
| Measurement Method | AC four-terminal method | ||||||||
| Measurement Frequency | 1 kHz | ||||||||
| Response Time | 5 ms approx. | ||||||||
| Open Terminal Voltage | 12 V peak | 15 V peak | |||||||
| Sampling Period (Frequency: 50 Hz/60 Hz) |
Meas. Speed | Fast | Medium | Slow | |||||
| ΩV | 60 ms | 300 ms | 600 ms | ||||||
| Ω or V | 40 ms | 200 ms | 400 ms | ||||||
| Allowable Total Line Res. (error detection) |
Range | 3 mΩ | 30 mΩ | 300 mΩ | 3 Ω | ||||
| Sense Line | 3 Ω | 3 Ω | 20 Ω | 20 Ω | |||||
| Source Line | 3 Ω | 3 Ω | 20 Ω | 200 Ω | |||||
| Function | Zero Adjustment | Yes | |||||||
| Meas. Current Pulse Output | Pulse, Continuous | ||||||||
| Statistical Calculations | Mean, Maximum, Minimum, Standard Deviation, Sample Standard Deviation, Process Capability Index (Dispersion), Process Capability Index (Deviation) | ||||||||
| Delay Time | On/Off, 1 ms to 9999 ms | ||||||||
| Average | 1, 2, 4, 8 times | ||||||||
| Save/Load | Up to 1000 | ||||||||
| Trigger | Internal, External, Manual | ||||||||
| Interface | Standard | RS232/485, USB, LAN, I/O, Analog Output | |||||||
| Optional | GPIB (HBT4000H series models only) | ||||||||
| Display | 4.3 inch LCD | ||||||||
| AC Input | 220 V ±10%, 47 to 63 Hz | ||||||||
| Dimension (W×H×D) | Low voltage: 208.5 mm × 84.5 mm × 264 mm | ||||||||
| High voltage: 208.5 mm × 84.5 mm × 344 mm | |||||||||









Reviews