Hantek DC Electronic Load 150v 30A 300W HDL2512A++
Buy it now
$945.78 incl. GST
FREE Shipping On All Orders
In Stock
When will I receive it?
7 days (estimated lead time)
Description
Hantek DC Electronic Load 150v 30A 300W HDL2512A++
The HDL2512/13/14/16/18 series programmable DC electronic loads provide precision testing with modes for constant current, constant voltage, constant resistance, and constant power. They support high-speed dynamic simulation, comprehensive protection functions, and multiple communication interfaces for remote control.
Features
- 4.3-inch LCD color display for clear and intuitive operation
- Resolution up to 0.1mV/1mV/0.1mA for accurate testing
- Supports list programming for complex current simulations
- USB, LAN, and RS232 interfaces with SCPI protocol
- Automatic OCP/OPP point capture with pass/fail evaluation
- Voltage rise/fall time and ripple measurement functions
- Measurement rate up to 100 kHz
- Remote sensing terminals for improved measurement accuracy
- Four operating modes: CV, CC, CR, and CP
- Battery, transient, and CR-LED simulation functions
Specifications
Model | Voltage | Current | Power | Resolution | Accuracy | Interface | Size |
HDL2512A++ | 150V | 30A | 300W | 0.1mv/0.1mA | ±(0.025%+0.025%FS)/ ±(0.05%+0.05%FS) | USB,RS232,LAN | 1/2 2U |
Waveform display and record
It can real-time display and record the change process of current, voltage, resistance and power value under various modes, and generate dynamic curve for storage.


CC: Constant Current
Regardless of the input voltage change, the load will pull load according to the set current, making the load work in constant current mode.
CV: Constant Voltage
In this mode, the load maintains the input voltage at a constant value by pulling the load current.


CR: Constant Resistance
In this mode, the load is equated to a constant resistance; variable from 0.1 ohms to 7500 ohms.
CP: Constant Power
This mode will pull the load at a constant power.


Voltage rise/fall time test function and ripple measurement function
It can accurately assess the dynamic response and stability of the power supply, quickly locate transient anomalies and ripple exceeding the standard, and improve the debugging efficiency and reliability of power supply design.
OCP/OPP Test
The instrument automatically captures OCP and OPP points and determines whether the test results are out of the set specifications, saving the user's verification time for design verification and system generation.


List Features
The loads can accurately simulate complex arbitrary current patterns at high speeds, allowing for precision testing with multiple aligned loads.
Battery Function
Automatically stops the test when the battery drops to the end of voltage or has been discharged to the end of capacity or reaches the end of time. Ensures that the battery is not over-discharged and damaged.


Tran Function
This function can be used to test the dynamic characteristics of the device under test by switching the electronic load between two set parameters (A value and B value). Dynamic test modes can be categorized into continuous mode, pulse mode and flip-flop mode.
CR-LED
Increase the setting of diode on voltage, more realistically simulate the working principle of diode, to avoid the traditional CR mode voltage and current instability generated by the vibration.

Specifications
Model | HDL2512A++ | |||
Rated value (0~40 ℃) | Input Voltage | 0~150V | ||
Input Current | 0~3A | 0~30A | ||
Input Power | 300W | |||
Minimum operating voltage | 0.14V at 3A | 1.4V at 30A | ||
Constant Voltage mode | Range | 0.1~18V | 0.1~150V | |
Resolution | 1mV | 1mV | ||
Accuracy | ±(0.05%+0.02%FS) | ±(0.05%+0.025%FS) | ||
Constant current mode | Range | 0~3A | 0~30A | |
Resolution | 1mA | 1mA | ||
Accuracy | ±(0.05%+0.05%FS) | ±(0.05%+0.05%FS) | ||
Constant resistance mode *1 | Range | 0.1Ω~10Ω | 10Ω~7500Ω | |
Resolution | 16bit | |||
Accuracy | 0.01%+0.08S*2 | 0.01%+0.0008S | ||
Constant power mode *3 | Range | 300W | ||
Resolution | 1mW | |||
Accuracy | ±(0.1%+0.1%FS) | |||
Dynamic mode (CC mode) | ||||
T1&T2 | 20μS~3600S /Res:1μS | |||
Accuracy | 2μS±100ppm | |||
Rise/Fall rate *4 | 0.0001~0.2A/μS | 0.001~1.5A/μS | ||
Minimum rise time *5 | ≒10uS | ≒10uS | ||
Measurement range | ||||
Voltage readback value | Range | 0~18V | 0~150V | |
Resolution | 0.1 mV | 1 mV | ||
Accuracy | ±(0.025%+0.025%FS) | ±(0.025%+0.025%FS) | ||
Current readback value | Range | 0~3A | 0~30A | |
Resolution | 0.1mA | 1mA | ||
Accuracy | ±(0.05%+0.05%FS) | |||
Power readback value | Range | 300W | ||
Resolution | 1mW | |||
Accuracy | ±(0.1%+0.1%FS) | |||
Protection range | ||||
Overpower protection | ≒320W | |||
Overcurrent protection | ≒3.3A | ≒33A | ||
Specification | ||||
Short circuit | Current (CC) | ≒3.3/3A | ≒33/30A | |
Voltage (CV) | 0V | 0V | ||
Resistance (CR) | ≒40mΩ | ≒40mΩ | ||
Input terminal impedance | 500KΩ | |||
Interface | USB,RS232,LAN | |||
Dimension | 208.5mm*84.5mm*325mm |