Hantek HSA2030A Handheld Spectrum Analyser 9KHz~3.2GHz AC Coupled
Buy it now
$9,893.69 incl. GST
In Stock
Description
Main Specifications:
- Frequency range :9KHz~3.2GHz;
- Optimal sensitivity: -161dBm;
- RBW:10Hz to 1MHz.
- High protection portable design, sturdy and durable
- Ideal for field mobile use
- Built-in large capacity lithium battery, can work for more than 4 hours. 18650 rechargeable battery.
- USB/LAN communication, easy for long-range control.
- 5.6 inch highlight color display, 640*480 resolution, waveform display clearly.
Features:
- Frequency range: 9KHz-3.2GHz (tunable
to 9KHz) AC Coupled - Optimal sensitivity: -161dBm RBW:10Hz to 1MHz
- IP-51 High protection portable design, sturdy and durable, can be used in laboratory, more suitable for field mobile use.
- built-in large capacity lithium battery, can work for more than 4 hours. 18650 rechargeable battery.
- 5.6 inch highlight color display, 640*480 resolution, waveform display clearly.
- HSA2000 Series spectrum
analyzer has the lowest DANL and SSB phase noise, and narrowest RBW. It greatly
enhances the recognition ability to the spurious signal and noise signal. - Optional FM/AM modulation
analysis, including carrier power, modulation rate, AM depth/FM deviation,
SINAD and carrier frequency offset. - Standard spectrum feature. It can analyze the signal time stability,
and find out lacunar signal in communication system accurately. - Strong field strength test function, fit for the test
work in transmitter, base station and the antenna coverage site. It can show
the density of field strength or power. The
user could also calibrate gain or loss by using amplitude offset function. - HAS2000
Series has least RBW in the same level of analyzers, and can easily confirm, distinguish and measure two similar signals. - The 5.7 inch highlight color display
can provide accurate, bright and clear trace both inside and outside, no need
to move to shading place for work. - Short scanning time. It can fast catch
the data and help to locate and recognize the irregular transient disturbance
signal, and then optimize the testing time and accuracy. - Advanced built-in battery management
system is adopted. Standard super large capacity-7800mAh lithium battery, and
support 6 packs of 18650 battery pack which can keep measurement working in
site for over 4 hours. - Firm and tight mechanical structure,
close rubber sleeve pack, which is fit for harsh site work environment. - Integration USB Host & Device,
support USB flash disk memory, optional WIFI/LAN, which is convenient for
networking and long-range control. - Its PC software can achieve the
management and storage of testing data.
Specifications
Parameters |
|||
Model |
HSA2030A |
HSA2030B |
|
Frequency |
|||
Frequency Range |
9KHz~3.2GHz |
9KHz~3.2GHz |
|
Frequency |
1Hz |
||
Reference |
10MHz |
||
Frequency |
±(frequency |
||
Internal 10MHz Accuracy |
Aging rate |
±1ppm/year(0℃~50℃,Reference |
|
Temperature stability |
±1ppm/year |
||
Marker |
(Frequency |
||
Resolution Bandwidth(RBW) |
|||
-3dBBandwidth |
10Hz to |
||
Accuracy |
±5% |
||
Resolution Filter |
<5:1nominal |
||
Video Bandwidth(VBW) |
-3dBbandwidth |
1Hz to 1MHz,1-3-10 sequence |
|
Accuracy |
±10% |
||
Displayed Average |
|||
9K~1MHz |
Preamp off |
-108dBm,typical -127dBm |
|
1MHz |
-128dBm,typical-146dBm |
||
10MHz |
-142dBm,typical-146dBm |
||
500MHz |
-141dBm,typical-145dBm |
||
2.5GHz |
-136dBm,typical-140dBm |
||
9K~1MHz |
Preamp on |
-131dBm,typical-150dBm |
|
1MHz |
-148dBm,typical-163dBm |
||
10MHz |
-161dBm,typical-164dBm |
||
500MHz |
-159dBm,typical-162dBm |
||
2.5GHz |
-158dBm,typical-161dBm |
||
SSBPhase Noise |
|||
Carrier Offset(20℃~ 30℃,500MHz Central Frequency) |
10K |
< -92 |
|
30K |
< -93 |
||
100K |
< -95 |
||
1MHz |
< -117 |
||
Sweep Time |
|||
Range |
Span >100Hz |
2ms to 1000s |
|
Span=0Hz |
600ns to |
||
Sweep Mode |
Continuous, single |
||
Trigger Source |
Free run; |
||
Trigger slope |
Selectable |
||
Trigger delay |
Span =0Hz |
±12ms to |
|
Frequency Counter |
|||
Counter |
1Hz |
||
Accuracy |
±(marker |
||
Level Display |
|||
Log Scale and Units |
1 to 10 |
||
Linear Scale |
0 to |
||
Scale Unit |
dBm,dBmV,dBuV,Watts,Volts |
||
Sweep (Trace) Points |
461 |
||
Number of Markers |
4 |
||
Detectors |
Normal, positive |
||
Number of Traces |
4 |
||
Trace Functions |
Clear/write, |
||
Level Measurement |
±1.5dB(excluding 20~30℃,peak |
||
Reference Level |
|||
Setting Range |
-100dBm |
||
Setting Resolution |
Log scale |
0.01dB |
|
Linear scale |
Almost log(2.236μV to 7.07V) |
||
Amplitude |
|||
Maximum Safety |
Average continuous |
+33dBm |
|
DC input |
50Vdc |
||
Measurement |
9KHz~2MHz |
Displayed |
|
2MHz~3.2GHz |
Displayed |
||
Input |
0 to 51dB,1dB |
||
Spurious Response |
|||
Second Harmonic |
<65dBc,50MHz to |
||
Input Related Spurious |
<-75dBc,(input |
||
Residual response (inherent) |
<-90dBm,typical -98dBm(Input |
||
RF Input (at Tuned |
10MHz to |
<1.5:1, nominal Attenuator setting 10~20dB |
|
10MHzReference/External |
|||
Reference Iinput |
10MHz |
||
Reference Input |
0~10dBm |
||
Trigger Voltage |
5V TTLlevel |
||
Connector and |
N female;(50Ω) |
||
Gennral |
|||
Interface |
English,Chinese,Chinese |
||
Display Index |
5.7 inch,640*480 resolution,64M |
||
Temperature Range |
Working |
-10℃ to +50℃,(battery:0℃ to 50℃) |
|
Storage |
-40℃ to +70℃,(battery :-20℃ to 50℃) |
||
Relative Humidity |
<95% |
||
Weight |
2.9kg(with |
||
Size |
260m X |
||
Power |
Input voltage |
DC:12-17V, |
|
AC |
40Hz to 60Hz |
||
Power |
Maximum 32W |
Additional information
Weight | 2.9 kg |
---|---|
Dimensions | 26 × 22 × 7 cm |
Reviews
There are no reviews yet.